EasyFill & EasyVent

Less assembly on site. A coordinated fill and vent system. EasyFill remote fill points and EasyVent vent stacks simplify underground petrol and diesel tank installations at forecourts and fleet fuelling depots. Factory-assembled, tightness-tested modules bring the key components together, with scalable frames, vapour recovery options and a choice of vent risers to suit your project.

Related Products

Underground tanks · Forecourts · Fleet depots

Put less work into building your fill and vent system.

Every underground fuel installation needs a practical arrangement for tanker deliveries and tank venting. EasyFill and EasyVent bring these components together in modular assemblies, reducing the separate fittings and assembly work your installation team needs to manage on site.

Specify the arrangement with PFS, then connect the selected assemblies into your underground pipework. The result is an orderly, consistent installation with serviceable components and a professional finish.

Illustrated EasyFill remote fill frame positioned in front of an EasyVent stack with five risers

Illustrative configuration. Fill frames, vent frames, risers and vapour recovery components are selected to suit the installation.

A practical advantage for installers and site operators

Move assembly work off site

Factory assembly and tightness testing reduce the component-by-component build your team has to carry out during installation. Pre-fitted PE stubs provide defined connection points for the underground pipework.

Simplify the equipment schedule

Choose a coordinated fill and vent arrangement with PFS rather than assembling a parts list from scratch. We can help check frame capacity, fuel grades, vapour recovery connections and the riser equipment required.

Keep routine servicing accessible

Threaded EasyFill adaptors can be replaced individually if damaged. EasyVent options with low-level pressure/vacuum valves bring those valves within easier reach for inspection, testing and maintenance.

Create a consistent site standard

Modular frames and regular fill-point spacing provide a neat, repeatable arrangement for a single installation or a wider forecourt or fleet-depot programme.

Two systems, selected around your tank layout

EasyFill: remote tanker fill points

Bring underground tank fill connections together at the designated delivery position. Powder-coated frames carry galvanised fill elbows, threaded fill adaptors and caps, with optional Stage Ib vapour recovery equipment.

  • 110 mm PE fill stubs provide the below-ground pipe connection points.
  • One to six fill positions per assembly, using the modular frame range with unused positions blanked as required.
  • Frames bolt together for seven or more fills, retaining 300 mm fill-position centres across adjoining frames.
  • Optional remote VR1 connection uses a 90 mm PE stub to link the fill area to the vent manifold.

View EasyFill assemblies

EasyVent: coordinated tank vent stacks

Organise tank vents in a supported frame, with stainless-steel vapour recovery manifolds where required. Select petrol and diesel riser kits separately to match the tank schedule.

  • 63 mm PE vent stubs connect to the underground vent lines.
  • Modular frame and manifold arrangements accommodate the number of tank vents required.
  • 2-inch aluminium riser options include petrol and diesel configurations.
  • Sliding goal-post and cross-bar supports allow riser components to be assembled and clipped at low level before the supports are raised and secured.

View EasyVent frames, risers and VR1 kits

Configured for retail forecourts and private fleet fuelling

Petrol and mixed-fuel forecourts

Coordinate the fill positions, petrol vent manifold and Stage Ib vapour return connection around the delivery area. The vapour recovery connection can sit at the vent stack or at a remote EasyFill frame, depending on the site layout.

Petrol vents can connect through the selected VR1 manifold; diesel vents follow their separate vent arrangement. Choose the appropriate petrol P/V valve configuration and riser equipment alongside the frames.

Diesel fleet and commercial depots

For underground diesel tanks at bus depots, distribution centres and private fleet sites, EasyFill provides a grouped delivery point while EasyVent supports the corresponding diesel vents.

Select diesel-only equipment to suit the installation, with a clear schedule of fill positions, vent lines and risers. The same modular approach supports both compact sites and installations with several tanks.

Build a complete equipment schedule

  1. List the tanks and compartments. Identify each fuel grade and the number of separate fill and vent connections.
  2. Select the EasyFill arrangement. Confirm the fill positions, frame combination, adaptors, caps and any vapour recovery connection.
  3. Select the EasyVent frame and manifold. Match the vent positions and petrol/diesel split to the tank schedule.
  4. Add risers and VR1 kits. Specify petrol or diesel risers, high-level or low-level P/V valve options where applicable, and direct or remote vapour recovery connections.
  5. Check the pipework interfaces. Confirm pipe sizes, materials and the transition fittings needed to connect the PE stubs to your chosen underground pipework system.

Specify the risers as well as the frame

EasyVent vent risers are ordered separately. Include the required riser kits and VR1 connection equipment in the quotation so the supplied package matches the intended installation.

Choose the P/V valve position for future access

Where low-level P/V valves are selected, routine valve access moves down from the top of the stack. Conventional high-level valve arrangements are also available. Confirm the riser configuration and access requirements for the whole vent installation when specifying the equipment.

Factory testing covers the supplied assembly. The connected site installation still requires its own testing and commissioning.

Product information for your project

Use the EasyFill & EasyVent brochure to review the modular range, assembly illustrations and connection options. PFS can help turn your tank schedule and layout into a coordinated equipment quotation.

Send us your tank schedule. We’ll help put the package together.

Tell us the number of tanks or compartments, fuel grades, fill and vent positions, underground pipework system and vapour recovery requirements. Include a site sketch or drawing if available.

We can help select the EasyFill and EasyVent components and coordinate them with your wider PFS equipment order, including underground pipework, tank fittings, gauging, leak detection and identification signs.

Your Basket
Subtotal
Delivery() No shipping method available Delivery
Call
Discount
VAT
Total (inc VAT)
Total (ex VAT)

Your order contains no items